Get Adobe Flash player

Dosimeters and radiometers

LLC "Axelbant"


Radiation monitoring system to be installed on gates and doors SIG-08M (SNIIP, Russia)

Radiation monitoring system to be installed on gates and doors SIG-08M (SNIIP, Russia)Enlarge

1900000 руб.

excl.Shipping costs

Modification:

Delivery Time - 1.5 to 3 months depending on the availability of an undertaking for the production.

Purpose:

Radiation Monitoring System SIG-08M in different versions designed for continuous level of background radiation photon of radiation and alarm raising the relative importance of background radiation above a certain threshold.

Applied to the input of radiation monitoring at the bases of scrap metal, landfills of household and industrial waste (landfills), protected objects in banking.

The level of background radiation photon of radiation is controlled by the value of the quantity effective dose. The plant can be used to control (detection) movement of radioactive materials or items contaminated with radioactive substances, pedestrians or vehicles crossing the controlled space.
The plant can be used to monitor the radiation situation in the room and on site.
Use is considered:
SIG-08M1 with one pylon and the distance to the source of radiation of 1.5 m and speed of the controlled materials pedestrians (4,0 ± 0,4) km / h;
SIG-08M2 with two pylons with the distance between the pylons of 0.8 m and a maximum speed of the controlled materials pedestrians (4,0 ± 0,4) km / h;
SIG-08M2T two pylons with the distance between the pylons of 4 m and a maximum speed of the vehicle controlled material (10 ± 1) km / h
The plant can be used to detect nuclear materials.

Supplied with primary metrological verification.

Ingredients:

Pilon measurement in accordance with the map order (1 or 2);
Remote measurement series DNA;
Remote alarm series BSR.

Detection thresholds set by the external background 0.12 mSv / h

Detectable activity, MBq:

Model
241Am 137Cs 60Co Note
SIG-08M1 0,65 (1,15) 0,4 (0,6) 0,185 (0,28) Measuring control and one pylon with one detection unit (for door, control rackets)
SIG-08M2 0,11 (0,69) 0,05 (0,18) 0,02 (0,08) Measuring board and two pylons with a detection unit in each (for door, control rackets). The testing of vehicles.
SIG-08M2T 1,12 (1,8) 0,6 (0,82) 0,28 (0,32) Measuring board and two pylons with two detection units each (to be installed on the gate to control the vehicle)

In parentheses are the worst detection performance measurement geometry.

The frequency of false positives - no more than one false alarm for 8 hours of work in continuous monitoring.

Specifications:

Measurement range of effective dose of photon radiation mSv / h 0,05 - 3
Maximum permissible measurement error at a confidence level of 0,95,% ± 30
Energy range of detected photon, 0.01 to 1.25 MeV
The level of your background settings mSv / h, not more than 0.01
Nonlinearity measure effective dose for 137Cs radiation, no more,% / Sv / h 9
Operating time, hours, not less than 24
Volatility readings,%, not more than 10
Warm-up time, min, max 15
The setup of AC rated voltage, V 220 10% -15%
Frequency, Hz 50 ± 1
Power consumption, W, not more than 20

Overall dimensions, mm, not more
pylon - 1540h120h88,
console - 260h160h85,
Remote alarm - 100h100h85

Weight, kg, not more
pylon - 20
Remote - 2
Remote alarm - 0.6

Service life, years, at least 6

Installing stable operation in ambient temperatures from -30 to + 50 ° C. The additional error of not more than 3% at 10oC.
Setting steadily works at ambient relative humidity of 95% and a temperature of 35 ° C and lower temperatures, no condensation.
Installing stable operation during and after exposure to vibration with a frequency of 5-35 Hz and a displacement amplitude of 0.75 mm.
Installation works stably and robust to the effects of air pressure in the working conditions of use in a range from 84 to 106.7 kPa.
Installing stable when exposed to a constant magnetic field of intensity up to 40 A / m
RS-485 interface.

Search

Advanced search

Currencies
ADV
Профессиональный
дозиметр размером
с шариковую ручку?
betagamma.ru
+7 495 506-68-69
Профессиональный дозиметр гамма-излучения от производителя
Профессиональный
дозиметр размером
с шариковую ручку!

Warning: include(images/menu.jpg) [function.include]: failed to open stream: No such file or directory in /home/axelbant/betagamma.ru/docs/cache/%%A8^A80^A8041F99%%product_info.php.html.php on line 142

Warning: include() [function.include]: Failed opening 'images/menu.jpg' for inclusion (include_path='.:/home/axelbant/betagamma.ru/php') in /home/axelbant/betagamma.ru/docs/cache/%%A8^A80^A8041F99%%product_info.php.html.php on line 142