Measuring rod 1,7 m:
(+ 2800 руб.)
Dosimeter - radiometer MKS - 83B "Expert-M2" is intended to :
- Continuous measurement of personal dose equivalent (hereinafter - ED) external gamma and X-ray (hereinafter - the photon ) radiation;
- Continuous measurement of accumulation time and display accumulation time;
- Measurement of ambient dose equivalent rate of photon radiation (hereinafter - DER ) external photon ( X-ray and gamma ) radiation;
- Flux density of beta - particle sources and beta radiation from contaminated surfaces;
- Indication of the density of alpha particles from sources of alpha radiation from contaminated surfaces;
- Quick search of contaminated items or radioactive sources;
- When completing the measuring cuvette - the measurement of the volumetric activity by Cs (gamma ) and Strontium-Yttrium (beta) of samples of water, soil, food, plant products, etc.;
- Indication of the date, time and ambient temperature;
- When connected to a computer - the chronology of events indicating the accumulation of ED and general statistics measuring device programming;
- Graphical representation on the own indicator of stories of the dose rate measuring;
- Measurements area illumination with built-in LED flashlight ;
- When connecting external detection units, the measuring capabilities of the device is greatly enhanced.
Dosimeter is recommended for:
- Field activities in the of environmental protection;
- Implementation of security activities in emergency situations;
- Implementation of the production control of compliance with the legislation of the Russian industrial safety requirements for operation of hazardous production;
- Work to ensure a safe environment and health.
Dosimeter has bilingual (English/Russian ) inside the settings menu.
Power supply from the built lithium-polymer battery , which is charged via USB-port.
Used counter - "Beta-5".
Technical characteristics:
DER measurement range
from 0.01 microSv/h to 100 Sv/h
ED measuring range
from 0.01 to 999 Sv
Accumulation time display step:
when connected to the PC:
1 h
1 min
Photon energy range during the measurement of the dose rate
from 0.04 to 3.0 MeV
Energy dependence when measuring dose and dose rate of photon radiation relative radiation of Cesium-137 %
± 30 %
Anisotropy of sensitivity for cesium -137 and americium -241 in the angle 4p, within %
±40
Range of flux density of beta - particles from contaminated surfaces (strontium -90 , yttrium -90) ppm/(Cm2 × min)
3 – 104
Beta radiation detected energy lower limit, not higher, MeV
0,05
Measuring range of volumetric activity of samples with a density of 0.08 to 1.2 g/cm, Bq/ml (Bq /g):
cesium- 137
strontium -90 + yttrium -90
1×101 - 2×104
2,5 - 5×103
Maximum permissible relative error
±25 %.
Range of flux density indication of alpha particles from contaminated surfaces (plutonium -239 ) ppm/(Cm2 × min):
1×10 53
Maximum permissible relative error
±
Range of flux density indication of alpha particles from contaminated surfaces (plutonium -239 ) ppm/(Cm2 ×
1×4
Lower limit of the energy of the detected alpha particles, no more, MeV
3,0
Number of DER preset threshold
3
Number of ED preset thresholds
3
DER thresholds setting range
throughout all the range
ED thresholds setting range
throughout all the range
Instability of the dosimeter for 24 hours of continuous operation
±10 %.
Reaction time to sudden changes in the level measured velichiny (more than 10 times on the natural background )
1 sec
Continuous operation from a fully charged battery (when measured at the level of natural background radiation , without using of the backlight and Bluetooth module)
at least 120 hrs
Power supply from the built lithium polymer battery, nominal voltage 3.7V, or miniUSB connector when connect to any PC or charger via USB output
The archive
up to 3276 records (time and date, the measured value)
Full charging time
no more than 4 hours
Additional relative error of the temperature varies from -20 to +50 ° C
±10 %.
Additional relative error due to humidity changes from normal to 98% at 35 ° C
±10 %
Operating conditions
- Ambient temperatures from minus 15 to plus 50 ° C ;
- Relative humidity not more than 98% at temperature 35 ° C ;
- Atmospheric pressure from 84 to 106.7 kPa.
Overall dimensions
240x78x75 mm
Weight
no more than 500 g